Configuring Frame Relay
7-19
Do not configure a Backup Group Number on this DLCI at the
remote (non-initiating) end.
Enable Backup Protocol?
specifies that (if
Y
) this DLCI will be used as a non-initiating backup. The DLCI will
wait for a backup protocol message from the initiating end, telling the backup where
to send the rest of the messages.
Remote RLP/Port/DLCI
identifies the primary DLCI in the non-initiating (called "remote" for the purpose of
differentiating) node to which that this DLCI connects for normal operation. (A
remote RLP does not need to be configured if the remote device is a SmartSwitch 1800
or an FRX4000.)
The primary and all of its backup DLCIs in the non-initiating
node must be on the same RLP.
Switchover Timer
is the time the initiating node will wait after detecting a primary DLCI failure before
it checks for available backups.
Switchback Timer
is the time the initiating node will wait before switching from the backup to the
primary DLCI after the primary becomes active again. If set to the maximum of
65565
,
the backup will not switch to the primary unless it (the backup) fails.
Time to Hold Data While Waiting
is the time the node will queue data while waiting for a backup DLCI to become
active. If neither a backup nor the primary has not become active when this timer
expires, the data will be discarded.
Configuring Frame Relay PVCs Across the Node
An FRM PVC is a "permanent" connection between two physical ports in a node. This
allows communication between the attached devices as soon as they are powered up,
without the need to first establish a connection.
To display a list of current PVCs, press
[A]
at the PVC Configuration Menu (or
[A], [D],
[E], [A]
from the Main Menu). The display will list PVCs of all supported types: frame
relay, X.25, async, and async-to-X.25.
To add or change a PVC, press
[B]
at the PVC Configuration Menu and enter a 1–4
digit
Connection ID
, which is simply a number unique to this connection, that identifies
the PVC.
Summary of Contents for FRM
Page 4: ...iv Frame Relay Module 4 0 User Guide Rev 01 ...
Page 16: ......
Page 17: ...Section I Getting Started ...
Page 18: ......
Page 24: ......
Page 35: ...Section II Configuration ...
Page 36: ......
Page 58: ......
Page 123: ...Configuring X 25 8 35 ...
Page 124: ......
Page 168: ......
Page 198: ......
Page 248: ......
Page 254: ......
Page 255: ...Section III Operation ...
Page 256: ......
Page 272: ......
Page 300: ......
Page 350: ......
Page 351: ...Section IV Appendices ...
Page 352: ......
Page 358: ......
Page 364: ......
Page 370: ......
Page 374: ......
Page 378: ...C View Initialization Report D View Previous Initialization Report ...
Page 388: ......
Page 396: ......