
8-16
Frame Relay Module 4. 0 User G uide, Rev 01
1
Once this parameter has been selected for the first time,
1
becomes the default value.
2
1–7
if modulo 8,
1–127
if modulo 128. Changing this parameter will disable the link only
if the new value changes the modulus.
3
0
means the parameter is not used.
4
Maximum Packet Size
values are
128, 256, 512, 1024, 2048
, &
4096
.
Default Packet
Size
values are all of the above plus
16, 32
, &
64
. If X.25 will be run over this port, do
not configure a size greater than
2048
. If
4096
is specified, additional X.25 and frame
headers can make the frame too large.
2048
will not cause a problem, since larger frames
will simply be split, then re-assembled at the destination.
Mapped DLCI Number
is the Data Link Connection Identifier, which links the logical port to a logical con-
nection on the physical frame relay port. It must match the DLCI configured on the
device at the other end of the local (rather than end-to-end) connection.
Make sure no more than one of any interface type (logical port,
frame relay IP/IPX/LLC2 interface, or frame relay Bridge port)
is assigned the same DLCI.
Also make sure this DLCI is not configured as a Frame Relay
Backup DLCI or as part of an intra-nodal frame relay PVC.
Blocked Port Flag
causes the logical port to be disabled (
Y
) or enabled (
N
) (only if the physical port is
also enabled) at node IPL. The port will remain in that state until this parameter is
changed or an on-line enable (
[B], [B], [C]
from the Main Menu) or disable (
[B], [B], [A]
from the Main Menu) is performed.
Priority
prioritizes this logical port for intra-nodal traffic; the higher the number, the higher the
priority. (This priority has no effect on traffic exiting a node.)
Priorities are configured on all logical interfaces that use a physical frame relay port.
The device processor in the node uses these priorities to help determine the order in
which it will process protocols.
When configuring priorities, be careful to consider the types of
traffic being routed on other connections in the node.
Closed User Group Parameters
Pr eferential CUG Flag
Y/N
N
Pr eferential CUG
0–99
0
Incoming Access Allowed
Y/N
N
Outgoing Access Allowed
Y/N
N
Add/Change CUG
See explanation
n/a
Del ete CUG
See explanation
n/a
Displ ay All CUGs
See explanation
n/a
Table 8-2 Logical Port Parameters
Parameter
Valid Values
Default Value
(continued)
Summary of Contents for FRM
Page 4: ...iv Frame Relay Module 4 0 User Guide Rev 01 ...
Page 16: ......
Page 17: ...Section I Getting Started ...
Page 18: ......
Page 24: ......
Page 35: ...Section II Configuration ...
Page 36: ......
Page 58: ......
Page 123: ...Configuring X 25 8 35 ...
Page 124: ......
Page 168: ......
Page 198: ......
Page 248: ......
Page 254: ......
Page 255: ...Section III Operation ...
Page 256: ......
Page 272: ......
Page 300: ......
Page 350: ......
Page 351: ...Section IV Appendices ...
Page 352: ......
Page 358: ......
Page 364: ......
Page 370: ......
Page 374: ......
Page 378: ...C View Initialization Report D View Previous Initialization Report ...
Page 388: ......
Page 396: ......