Chapter 3: DLM6C-AA Setup
3-12
DLM6C-AA Overview and Setup Guide
Figure 3-6
Power Supply DC ON/OFF Switch and DC Input Power Strip
ONLY QUALIFIED PERSONNEL SHOULD PERFORM THESE
INSTALLATION PROCEDURES.
TO REDUCE THE RISK OF ELECTRIC SHOCK OR ENERGY
HAZARDS:
•
CONNECT TO A RELIABLY GROUNDED 48/60 VDC
SELV SOURCE.
•
ENSURE THE BRANCH CIRCUIT OVERCURRENT
PROTECTION IS RATED AT A MINIMUM
OF 25 A.
•
USE 10 AWG
SOLID COPPER CONDUCTORS ONLY.
•
ENSURE THAT A READILY ACCESSIBLE
DISCONNECT DEVICE THAT IS SUITABLY
APPROVED AND RATED, IS INCORPORATED IN
THE FIELD WIRING.
TO BE INSTALLED IN A RESTRICTED ACCESS AREA IN
ACCORDANCE WITH THE NEC OR THE AUTHORITY
HAVING JURISDICTION.
ON/OFF
DC Input Power Strip
LKG-10804-98F