Powering Up a DLM6C-AA with a DC Power Supply
DLM6C-AA Overview and Setup Guide
3-13
DC Power Supply Requirement for Each Supply
Each dc power supply input requires either a 48 Vdc or 60 Vdc power
source, rated at a minimum of 17 Amps.
Installation Requirement
Each dc power supply input requires either a 48 Vdc or 60 Vdc power
source supplied by three 10 AWG copper wires. These wires must be
terminated with either ring or spade terminals that accept a #6 screw.
3.4.1
Connecting an HA205-MD to 48/60 Vdc Source
To connect the HA205-MD to a 48/60 Vdc power source, face the front of
the power supply, then refer to
Figure 3-7
and proceed as follows:
Figure 3-7
48/60 Vdc Power Supply Connections
1.
Connect the ground
terminal of the dc input power strip to an
appropriate earth ground.
2.
Refer to
Figure 3-7
for the proper connections to a 48/60 Vdc power
source. Then connect the output leads of the 48/60 Vdc power source
being used to the negative (-) and positive (+) terminals on the dc input
power strip.
To prevent injury or damage to the equipment, remove power
from a 48/60 Vdc power source before proceeding with the
following steps.
DC Input Power Strip
+
-
Earth
Ground
ON/OFF
48 or 60 Vdc
Power Source
LKG-10805-98F