Other Configuration commands
1) Adding & Changing Login Banner
2) Changing Disconnect character
3) Turning PB Flow Control on or Off
4) Set the Number of Dial rings on Auto Answer
5) Set the Inactivity Timeout for Inactive data
6) Turn Login prompt Display on or off
(Please note: <
CR
> = Enter)
Abbreviated
Command
Admin 1
Admin 2
Parameters/Values
Description
BN=
254 Characters
(including spaces)
BN=<
CR
>Disables banner
Adds a Security Banner at the Login Prompt.
Use
\n
as the new line command. When finished with banner text press
<
CR
>
Please note
: word wrap must be disabled if the banner text enters a new
line
Example: This is a secure site
\n
Unauthorised attempts will be
prosecuted.<
CR
>
This would read at the Login:
This is a secure site
Unauthorized attempts will be prosecuted
To remove Banner type: BN=<
CR
>
DC=
Any Single Character
Change the Disconnect Character (Example Semi Colon (;)
(
Default:
CTRL+XXX)
Example: DC=D<
CR
>
Disconnect character is now
D
(Pressed 3 times quickly to return to the
Main Menu.
PBFC=
On or Off
Turns PB Flow Control on or Off ( Example PBFC=On)
(
Default:
On)
Example: PBFC=off<
CR
>
PB Flow Control is turned OFF
Example: PBFC=On<
CR
>
PB Flow Control is turned ON
DR=
1-9
Sets the number of dial rings before the FF06-6P answers the call
(
Default:
2)
Example: DR=6<
CR
>
The Pushkablue unit will answer on 6 rings
IT=
1-99
Changes the Inactivity time out parameter from 1-99 minutes (0=Never)
(
Default:
5)
Example: IT=20<
CR
>
The Pushkablue unit will disconnect the call or Terminal session when
data inactivity is more than 20 minutes.
LPD=
On/Off
Changes the Login Display prompt On or Off (
Default:
On)
Example: LPD=Off<
CR
>
This removes the word LOGIN: when the modems synchronize
Example: LPD=On<
CR
>
This enables the word LOGIN: to appear when the modems
Synchronize