7 | Maintenance
28 | 40
Instruction Manual MINK MM 1104-1142 BV ATEX_EN_en
●
Remove the clogging or have the machine repaired (contact Busch).
1
2 3
4
Description
1
Unscrew plugs
2
Connect pressurized air to the pressure
relief lines
3
Air pressure max. 0.2 bar (g)
4
Tighten plugs
1
Description
1
Tighten nuts
7.6
Coupling Maintenance
●
Check the coupling backlash and carry out a visual check.
●
Please refer to the coupling instruction manual (attached to the ATEX Accessories Book) for