5 | Installation
14 | 40
Instruction Manual MINK MM 1104-1142 BV ATEX_EN_en
Other values may apply after Busch approval
●
Make sure that the environment of the machine complies with the ATEX classification of the
machine according to the data given on the nameplate of the motor and the nameplate of the
machine (NP).
●
Make sure that the ambient conditions comply with the
●
Make sure that the environmental conditions comply with the protection class of the motor and
the electrical elements.
●
Make sure that the installation space or location is vented such that sufficient cooling of the
machine is provided.
●
Make sure that cooling air inlets and outlets are not covered or obstructed and that the cooling
air flow is not affected adversely in any other way.
●
Make sure that the oil sight glass (OSG) remains easily visible.
●
Make sure that enough space remains for maintenance work.
●
Make sure that the machine is placed or mounted horizontally, a maximum of 1° in any direction
is acceptable.
●
24].
●
Make sure that all provided covers, guards, hoods, etc. are mounted.
If the machine is installed at an altitude greater than 1000 meters above sea level:
●
Contact your Busch representative, the motor should be derated or the ambient temperature
limited.
If the machine is installed at an altitude greater than 600 meters above sea level:
●
The vacuum relief valve (VRE) needs to be readjusted according to the altitude, contact your
Busch representatives.
●
Make sure that the monitoring devices are correctly connected and integrated into a control
system such that operation of the machine will be inhibited if the safety limit values are exceeded,
see
Electrical Connection of the Monitoring Devices
20].
If additional electrical components not included in scope of delivery should be added:
●
Make sure that they have a better or equal ATEX classification than that of the machine, see the
ATEX marking on the nameplate (NP).
For classification type "A", "B" and "C"
(see
ATEX Classifications and Associated Accessories
●
Make sure that the installation space or location is ventilated enough in order to prevent the
formation of an explosive area.