Technical Data | 12
Instruction Manual MINK MM 1104-1142 BV ATEX_EN_en
37 | 40
12
Technical Data
MM 1104 BVE
MM 1144 BVE
Nominal pumping speed
(50Hz/60Hz)
m³/h
62 / 75
80 / 95
Ultimate pressure
hPa (mbar)
abs.
60
60
Min. nominal motor rating
(50Hz/60Hz)
kW
1.5 / 1.7
Ex-motor: 2.2 / 2.2
2.2 / 2.4
Ex-motor: 2.2 / 2.2
Nominal motor speed
(50Hz/60Hz)
min
-1
1500 / 1800
1500 / 1800
Permitted motor speed
range
min
-1
600 … 1800
► ≥
60 hPa (mbar) abs.
600 … 1800
► ≥
60 hPa (mbar) abs.
Noise level at 400 hPa
(mbar) abs. suction pressure
(50Hz/60Hz)
dB(A)
66 / 70
66 / 70
Ambient temperature range °C
0 … 40*
0 … 40*
Inlet gas temperature range °C
0 … 40*
0 … 40*
Ambient pressure
Atmospheric pressure
Atmospheric pressure
Oil capacity
l
0.85
0.85
Weight approx. (50Hz/60Hz)
kg
~185**
~185 / 190**
Weight approx. with Ex-
motor
kg
200**
200**
MM 1102 BVE
MM 1142 BVE
Nominal pumping speed
(50Hz/60Hz)
m³/h
110 / 135
140 / 175
Ultimate pressure
hPa (mbar)
abs.
60
60
Min. nominal motor rating
(50Hz/60Hz)
kW
3.0 / 3.5
Ex-motor: 3.0 / 3.6
3.5 / 4.8
Ex-motor: 4.0 / 4.8
Nominal motor speed
(50Hz/60Hz)
min
-1
3000 / 3600
3000 / 3600
Permitted motor speed
range
min
-1
600 … 3600
► ≥
60 hPa (mbar) abs.
600 … 3600
► ≥
60 hPa (mbar) abs.
Noise level at 400 hPa
(mbar) abs. suction pressure
(50Hz/60Hz)
dB(A)
75 / 79
75 / 79
Ambient temperature range °C
0 … 40*
0 … 40*
Inlet gas temperature range °C
0 … 40*
0 … 40*
Ambient pressure
Atmospheric pressure
Atmospheric pressure
Oil capacity
l
0.85
0.85
Weight approx. (50Hz/60Hz)
kg
~180 / 190**
~185 / 195**
Weight approx. with Ex-
motor
kg
210**
210**
* In case of higher or lower temperatures, please consult your Busch representative.