Make sure that the ATEX marking of the coupling corresponds to the ATEX classification of the
machine.
●
Fit the second coupling hub on the motor shaft (separately delivered).
●
Axially adjust the sleeve in such a way until value "E" (or “L”) is reached.
●
When the coupling adjustment is done, lock the coupling hub by tightening the radial screw.
●
Mount the motor on the machine by including the coupling spider.
For further coupling information, go to
and download the instruction manual of the
ROTEX
®
coupling.
English
German
French
5.6
Electrical Connection
DANGER
Live wires.
Risk of electrical shock.
●
Electrical installation work must only be executed by qualified personnel.
●
Make sure that the power supply for the motor is compatible with the data on the nameplate of
the motor.
●
The electrical installation must comply with applicable national and international standards.
●
Provide a lockable disconnect switch on the power line so that the machine is completely secured
during maintenance tasks.
●
Provide an overload protection according to EN 60204-1 for the motor.
●
Busch recommends installing a D-curve circuit breaker.
●
Make sure that the motor of the machine will not be affected by electric or electromagnetic
disturbance from the mains; if necessary seek advice from Busch.
●
Connect the protective earth conductor.
●
Electrically connect the motor.
NOTICE
Incorrect connection.
Risk of damage to the motor and temperature switches!
●
The wiring diagrams given below are typical. Check the inside of the terminal box for motor and
temperature switches connection instructions/diagrams.