Installation | 5
Instruction Manual MINK MM 1104-1142 BV ATEX_EN_en
17 | 40
1
Description
1
4 mm hex key
The oil level should stay constant over the lifetime of the oil. If the level does fall, this indicates a leak
and the machine requires repair.
5.5
Fitting the Coupling
1
2
3
4
Description
1
Coupling hub (machine side)
2
Coupling spider
3
Coupling hub (motor side)
4
Set screw; max. admissible torque: 10
Nm
In case of a machine delivery without motor: