5 | Installation
16 | 40
Instruction Manual MINK MM 1104-1142 BV ATEX_EN_en
Connection size(s):
– G1 for MM 1104 BV, MM 1144 BV
– R1 for MM 1102 BV, MM 1142 BV
Depending on the specific configuration ordered, other connection dimensions may apply.
Unless the aspirated air is discharged to the environment right at the machine:
●
Make sure that the discharge line either slopes away from the machine or provide a liquid
separator or a siphon with a drain cock, so that no liquids can flow back into the machine.
5.3
Earth Connection
In order to prevent the machine from creating an electrostatic charge:
●
Connect the earth connection of the machine (ECP)
If an inlet filter (IF) being installed:
●
Connect the earth connection of the inlet filter (ECI) in addition to the earth connection of the
machine.
1
2
Description
1
Inlet filter earth connection (ECI)
2
Ground to earth
5.4
Filling Oil
NOTICE
Use of an inappropriate oil.
Risk of premature failure!
Loss of efficiency!
●
Only use an oil type which has previously been approved and recommended by Busch.
For oil type and oil capacity see
38].