DP, MB
motors
overcurrent
Current gauge
EOCR
Depends on alarm function
set in the PLC for
overcurrent. Set at factory:
General Stop ie. the
contactors open and remove
power to motors.
For DP overcurrent: EMO
urgent switch off.
For MB overcurrent: all MB
pumps stop.
S
Cylinder
overtempera-
ture
Temperature
switch TS 3
Depends on alarm function
set in the PLC for cylinder
temperature. Set at factory:
General Stop ie. the
contactors open and remove
power to motors
S
Cooling water
flow low
Water flow
switch FS 1/
FS 2
Depends on alarm function
set in the PLC for water
flow. Set at factory: General
Stop ie. the contactors open
and remove power to mo-
tors
S
Nitrogen flow
to low
Nitrogen
flowmeter FME
Depends on alarm function
set in the PLC for nitrogen
flow. Set at factory: General
Stop ie. the vacuum system
continues running with the
alarm
S
Cooling liquid
flow to low
Flow controller
FCV
The contactors open and cut
the engine supply after 30
seconds
S
Excessive oil
temperature
(t°>105°C)
Temperature
switch TS 1
The contactors open and cut
the engine supply after 120
seconds (changeable dura-
tion)
S
H= Hardware, S= Software
“X” is the number of the DP or MB vacuum pump
Safety
COBRA DS 8163 A
Page 14
0870772605