Model 9180
burster
Digital Panelmeter
Page 4-25
Fig. 4.3.3a
Output option RS232C
4.3.3
Installation of the card
Remove the device from the network!
Remove the electronics from the housing and open the location marked in Fig. 4.3.3a.
This opening is designed for the RS232C output.
The options card is inserted into terminal slot M1.
Carefully press the nose of the card into the slot on the base plate until it latches in. If during
operation the device vibrates, it makes sense to permanently solder the card onto the base plate
at the lashes provided.
Before reinserting the device back into the housing, you should check to see if access to the
programming level is disabled (see page 2-5 for the DIP switch).
Exit site for
connection socket