MYX-12384 REPLICATOR 1100 (for DC lifters)
“
SOL
”
connector I/O ratings
Note: All solenoids are served by the same fuse, FU2, on the rear
panel. Maximum total current of the solenoids is limited by this fuse.
PIN #
DESCRIPTION
RATINGS
9
Input - Solenoid Hot
24 V max AC, 50/60 Hz, or 24 V max DC, 6.3 A max
33
Input - Solenoid Neutral or common
Neutral or common for pin 9
2, 6, 11, 17,
21, 24, 35, 30
Output - Solenoid Neutral
Neutral for pins 1, 5, 10, 16, 20, 23, 34, and 29
3, 7, 12, 18,
22, 25, 36, 31
Chassis ground
18 AWG wire
1
Oxygen Vent Solenoid Output
24 V max AC, 50/60 Hz, or 24 V max DC.
2 A max, but on same 6.3 A fuse with 7 other solenoid
outputs.
5
Second Stage Cut O2 Solenoid
Output
24 V max AC, 50/60 Hz, or 24 V max DC.
2 A max, but on same 6.3 A fuse with 7 other solenoid
outputs.
10
Lo Preheat Solenoid Output
24 V max AC, 50/60 Hz, or 24 V max DC.
2 A max, but on same 6.3 A fuse with 7 other solenoid
outputs.
16
Ignite Solenoid Output
24 V max AC, 50/60 Hz, or 24 V max DC.
2 A max, but on same 6.3 A fuse with 7 other solenoid
outputs.
20
First Stage Cut Oxygen Solenoid
Output
24 V max AC, 50/60 Hz, or 24 V max DC.
2 A max, but on same 6.3 A fuse with 7 other solenoid
outputs.
23
Water Solenoid Output
24 V max AC, 50/60 Hz, or 24 V max DC.
2 A max, but on same 6.3 A fuse with 7 other solenoid
outputs.
34
Hi Preheat Solenoid Output
24 V max AC, 50/60 Hz, or 24 V max DC.
2 A max, but on same 6.3 A fuse with 7 other solenoid
outputs.
29
Auxilliary Solenoid Output
24 V max AC, 50/60 Hz, or 24 V max DC.
2 A max, but on same 6.3 A fuse with 7 other solenoid
outputs.
Summary of Contents for 1100 CD
Page 20: ...Figure 1 3 Slowdown Marker ...
Page 34: ...BLANK ...
Page 56: ...BLANK ...
Page 58: ...Tools 40 Torch Lifter Controls 26 Tracer Function Keys 21 28 ...
Page 63: ...PART 7 DRAWINGS PART 7 DRAWINGS ...
Page 64: ...BLANK ...