MYX-12383 REPLICATOR 1100 (for AC lifters)
“
LIFT
”
connector I/O ratings Note: All lifters are served by the same fuse,
FU3, 6.3 A maximum, on the rear panel. Maximum total current of
the lifters is limited by this fuse.
PIN # DESCRIPTION
RATINGS
10
Lifter 1 up switched output
Switched 24 V max AC, 50/60 Hz, 2 A max.
See note above.
5
Lifter 1 down switched output
Switched 24 V max AC, 50/60 Hz, 2 A max.
See note above.
11
Lifter 1 Hot un-switched output
Un-switched 24 V max AC Line, 50/60 Hz, max 2 A
See note above.
6
Lifter 1 Neutral un-switched output
Un-switched 24 V max AC Neutral, 50/60 Hz, max 2 A.
See FU3 note above.
1
Chassis Ground
18 AWG wire
2
Lifter 2 up switched output
Switched 24 V max AC, 50/60 Hz, 2 A max.
See note above.
3
Lifter 2 down switched output
Switched 24 V max AC, 50/60 Hz, 2 A max.
See note above.
7
Lifter 2 Hot un-switched output
Un-switched 24 V max AC Line, 50/60 Hz, max 2 A
See note above.
8
Lifter 2 Neutral un-switched output
Un-switched 24 V max AC Neutral, 50/60 Hz, max 2 A
See note above.
4
Chassis Ground
18 AWG wire
9
Lifter 3 up switched output
Switched 24 V max AC, 50/60 Hz, 2 A max. See note above.
15
Lifter 3 down switched output
Switched 24 V max AC, 50/60 Hz, 2 A max.
See note above.
14
Lifter 3 Hot un-switched output
Un-switched 24 V max AC Line, 50/60 Hz, max 2 A
See note above.
21
Lifter 3 Neutral un-switched output
Un-switched 24 V max AC Neutral, 50/60 Hz, max 2 A
See note above.
22
Chassis Ground
18 AWG wire
28
Lifter 4 up switched output
Switched 24 V max AC, 50/60 Hz, 2 A max.
See note above.
33
Lifter 4 down switched output
Switched 24 V max AC, 50/60 Hz, 2 A max.
See note above.
Summary of Contents for 1100 CD
Page 20: ...Figure 1 3 Slowdown Marker ...
Page 34: ...BLANK ...
Page 56: ...BLANK ...
Page 58: ...Tools 40 Torch Lifter Controls 26 Tracer Function Keys 21 28 ...
Page 63: ...PART 7 DRAWINGS PART 7 DRAWINGS ...
Page 64: ...BLANK ...