MYX-12383 REPLICATOR 1100 (for AC lifters)
“
PLAS
”
connector I/O ratings
PIN #
DESCRIPTION
RATINGS
1, 2
Plasma Start relay normally closed contacts
30 VDC or 230 VAC, 2 A
1, 3
Plasma Start relay normally open contacts
30 VDC or 230 VAC, 2 A
4, 5
Plasma Stop relay normally closed contacts
30 VDC or 230 VAC, 2 A
4, 6
Plasma Stop relay normally open contacts
30 VDC or 230 VAC, 2 A
7, 8
Height Sensor Disable relay normally open contacts
30 VDC or 230 VAC, 2 A
7, 9
Height Sensor Disable relay normally closed contacts
30 VDC or 230 VAC, 2 A
15
Arc On Sense input
24-115 V DC or AC, 30 mA max
16
Arc On Sense input
115-230 V DC or AC, 30 mA max
14
Arc On Sense input
Return for signal of pin 15 or 16.
MYX-12383 REPLICATOR 1100 (for AC lifters)
“
RMTR
”
connector I/O ratings
PIN #
DESCRIPTION
RATINGS
3, 5
Clutch Switch on front panel
24 V max, AC or DC, 3 A max
2, 8
Rail Axis Motor
± 30 VDC, 4 A
1, 4
Rail Axis Tach
20 V, 5 mA Max
6
Input for + limit switch
10 mA required to pull the 24VDC input to ground
7
Input common for limit switches
25 mA, to be used as common for pins 6 and 9.
9
Input for - limit switch
10 mA required to pull the 24VDC input to ground
MYX-12383 REPLICATOR 1100 (for AC lifters)
“
CMTR
”
connector I/O ratings
PIN # DESCRIPTION
RATINGS
3, 5
Clutch Switch on front panel
24 V max, AC or DC, 3 A max
2, 8
Cross axis Motor
± 30 VDC, 4 A
1, 4
Cross Axis Tach
20 V, 5 mA Max
6
Input for + limit switch
10 mA required to pull the 24 VDC input to ground
7
Input common for limit switches
25 mA, to be used as common for pins 6 and 9.
9
Input for - limit switch
10 mA required to pull the 24 VDC input to ground