9.3.5.
Pellet hopper:
- Completely empty the pellet hopper
- Clean the pellet ash residues from the
bottom of the hopper. Use a scraper and
a vacuum cleaner.
10. CONTROLLER UNIT
10.1. Controller view. Explanation of
buttons and indicators.
LCD screen:
The
controller
screen displays the
information for the
operation of the
facility.
Explanation
of
buttons:
When logging into a menu, use
arrow keys
UP
and
DOWN
to move from one page to another.
Enter
button
permits adjustment of
the page.
When adjustment is enabled, use arrow
keys
UP
and
DOWN
to adjust
the parameter.
Press
ENTER
to change the
parameters.
Press
F
to exit the menu.
Confirm with
Enter
button
.
Display symbols explanation:
Auto Clean symbol appears in right
upper part of display. Active auto
cleaning symbol means boiler automatic
cleaning mode.
Crossed-out flame symbol appears
in upper right part of display. Means
that the boiler enters into Extinguish
mode.
CH priority
/Radiator /symbol
appears in upper part of display.
Means than Central Heating priority is set
to heat up the central heating.
Domestic Hot Water
/shower/
priority symbol appears in upper
part of display. Means than
DHW
priority
is set to heat up the domestic hot
water. When set DHW temperature is
reached, DHW pump stops and CH pump
is activated.
Parallel pumps /shower and
radiator/ symbol appears in upper
part of display. Means that is set
equal priority to both pumps. They work
in parallel and are controlled by
temperature sensors.
Summer mode
/shower and sun/
symbol means than is set Summer
heating mode. Only DHW pump is active.
Burner flame symbol appears in
upper right part of display. Means
that burner is activated. Burner goes into
Ignition mode and upcoming boiler fire
up.
Flame 2 symbol means
Maximum
output mode
of boiler. In this mode
the boiler operates at maximum output.
Flame 1 symbol means
Low output
mode
of boiler. In this mode the
boiler operates at minimum output.
The notice "
Hi
" appearance on the
screen
where
the
boiler
temperature is displayed means
that the measured boiler body
temperature is above 120°C. Flashing and
beeping alarm is activated. When the
issue is corrected, notification can be
deleted. Disconnect fuel auger from boiler
plug-in socket. Upon any such occurrence
please contact immediately your installer
for system checkup.
Boiler increased temperature.
Those two symbols appearance on
the screen where the boiler