9
.2. Important recommendations for
long-lasting and correct operation of the
boiler
- For assembly and installation of the
burner follow the requirements in this
manual.
- Use only recommended in this manual
fuel.
- Disassemble the burner from the boiler
body before clean it. Depending on fuel
and burner settings, clean the pellet
burner once a month.
- User`s training for operation and
maintenance of burner is performed by
an authorized installer or service shop.
Failure to observe the installation
and operating requirements
described in the manual and
the service booklet voids the
warranty.
9.3. Requirements for the cleaning and
maintenance of PelleBurn pellet boiler
with pellet burner.
Attention! Important instructions
regarding cleaning of boiler
Caution! Hot surfaces.
Before cleaning the boiler, make
sure the fire in it has died out and
the boiler has cooled down.
- It is mandatory to clean the ashes from
the container once a week. Unhook the
buckles on both sides of ash container.
Pull ash container out of the boiler and
clean it.
Once you have emptied the container of
ashes, please make sure you close the
container cover tightly, buckle-lock it to
the container buckles, then buckle-lock
the container to the boiler buckles.
Diagram 13
- It is mandatory to clean once a month
the combustion chamber of the burner.
Attention!
Cleaning
and
maintenance of the boiler
should be carried out only by
an authorised installer/service
shop.
Before the start of the heating season
it is mandatory to check and clean the
following components of the boiler:
9.3.1 Cleaning and maintenance of
suction fan
Diagram 14
- Remove the two parts of the boiler top
cover by lifting them upwards
1
2
Diagram 15