Table 3. European Certification of Wood Pellets for Heating Purposes
Parameters
Units
ENplus-A1
ENplus-A2
EN-B
Diameter
mm
6 (± 1)
8 (± 1)
6 (± 1)
8 (± 1)
6 (± 1)
8 (± 1)
Length
mm
15 ≤ L ≤ 40
1)
15 ≤ L ≤ 40
1)
15 ≤ L ≤ 40
1)
Bulk density
kg / m
2
≥ 600
≥ 600
≥ 600
Calorific/heating value MJ / kg
≥ 16,5-19
≥ 16,3-19
≥ 16,0-19
Humidity /moisture
Ма .-%
≤ 10
≤ 10
≤ 10
Dust
Ма .-%
≤ 1
3)
≤ 1
3)
≤ 1
3)
Mechanical durability
Ма .-%
≥ 97,5
4)
≥ 97,5
4)
≥ 96,5
4)
Ash
Ма .-%
2)
≤ 0,7
≤ 1,5
≤ 3,5
Melting point of ash
°C
≥ 1200
≥ 1100
-
Chlorine content
Ма .-%
2)
≤ 0,02
≤ 0,02
≤ 0,03
Sulfur content
Ма .-%
2)
≤ 0,03
≤ 0,03
≤ 0,04
Nitrogen content
Ма .-%
2)
≤ 0,3
≤ 0,3
≤ 1,0
Copper content
mg / kg
2)
≤ 10
≤ 10
≤ 10
Chromium content
mg / kg
2)
≤ 10
≤ 10
≤ 10
Arsenic content
mg / kg
2)
≤ 1,0
≤ 1,0
≤ 1,0
Cadmium content
mg / kg
2)
≤ 0,5
≤ 0,5
≤ 0,5
Mercury content
mg / kg
2)
≤ 0,1
≤ 0,1
≤ 0,1
Lead content
mg / kg
2)
≤ 10
≤ 10
≤ 10
Nickel content
mg / kg
2)
≤ 10
≤ 10
≤ 10
Zinc content
mg / kg
2)
≤ 100
≤ 100
≤ 100
1)
not more than 1% of the pellets may be longer than 40 mm, max. length 45 mm;
2)
dry weight;
3)
particles <3.15 mm, particulate matter, before handing over the goods;
4)
measurements with Ligno-Tester limit value ≥ 97,7% by weight.
4. TRANSPORTATION OF THE BOILER
We recommend to transport the heating
boiler to the installation site in its
packaging placed on the pallet. During
transport and installation, depending on
the weight, suitable safety devices should
be used in accordance with Directive
2006/42/EC.
When transporting items weighing more
than 30 kg, the use of pallet jack, fork
truck or other hoisting devices is a must.
Product must be in original packaging
following the instructions on the label -
to be protected from adverse weather
conditions (snow, rain and dust) from
the shocks, and other activities likely to
cause damage. In case of malfunction of