TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
When the last of these set cycles has been
executed, auger will stop automatically
and controller will activate automatically
the option
Weight.
When option
Weight
is active enter the weight of pellets. To do
this you must have electronic scale.
Entering the amount of
weighted pellets:
Use this menu to enter
the amount of weighted
pellets when all set cycles have been
executed
.
Use accurate scales with range
of at least 10 grams. Of the total
weight (pellets and plastic bag)
subtract the weight of the bag to
get the right amount of pellets
during measurement!
Usе "Up arrow" and "Down arrow"
buttons to enter the amount of weighted
pellets as round the amount to 10 grams.
Press
"F"
button to switch to next
submenu.
Applying the calculated
feed:
In
this
sub-menu
controller automatically
calculates the interval for fuel feeding
during combustion cycle.
Example:
(see picture) for combustion
cycle of
20 sec.
calculated fuel feeding
is
8.8 sec.
Use "Up arrow" and "Down
arrow" button to
Apply
or
Cancel
calculated value. By confirmation with
button “Apply” You confirm this and this
setting is saved for maximum power
setup.
Press
„F”
button to confirm and exit the
menu.
10.3.2. Cleaning setup and Clean Ashes
The burner performs automatic cleaning
before each ignition and shut-down.
You can use this menu
to adjust the running
time of the main fan
(
FAN
) and of the
cleaning motor (
Cleaner
).
Select the desired option using the
navigation arrows. Use the „
Enter
” button
to open the next parameter. Time-setting
for parameter
(FAN)
determines burner
cleaning, damping and ignition of the
boiler.
Important: With the arrow keys up
and down arrow can switch from
one to the next page or return to
the previous page.
Use Cleaner
On Start
On Stop
In this submenu you can
activate or deactivate
the automatic cleaning
of the burner in Ignition
(Start)
mode and extinguished
(Stop)
mode.
The checkmark in the box indicates that
the automatic cleaning system is active.
Setting up the run-time
of the main boiler flue
pipe cleaning motor.
Select the desired
option using the navigation arrows. Use
the „
Enter
” button to open the next
parameter.
Setting up the runtime
of the ash carrier screw
taking the ashes from
the boiler to the ash and
soot container. The ash carrier screw
runtime is set in seconds. The runtime of
main pellet auger is set in number of
cycles. Once the set number of cycles is
completed, the boiler will launch the self-
cleaning procedure after which the main
auger will start automatically.
Select the desired option using the