38
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
Use this submenu to
adjust the internal
auger of the burner as a
percentage value of the operation ofthe
external pellet auger.
Example:
If the
external pellet auger runs for
10
seconds
and feeds fuel in the burner, the internal
auger will run for
20
seconds, if the setting
is
Duty 0-300%
(see picture).
The check mark in the box indicates that
the device is active.
Select the desired option using the
navigation arrows. Use the „
Enter
” button
to open the next parameter.
This menu allows you to
select maximum boiler
temperature. In other
words, the maximum
temperature to heat the boiler on which
the burner has been installed. The
maximum value for this setting is
85°С
.
Select the desired option using the
navigation arrows. Use the „
Enter
” button
to open the next parameter.
Use this menu to
conduct fan operation
test. You can control the
fan in real time, without
confirming anything, using only the
navigation arrows.
Test EFan Speed
Use this menu to test
exhaust gases fan. You
can control the fan in
real time, without
confirming anything, using only the
navigation arrows.
Important. This menu is for installers
only and it is active and visible only if the
controller is in „Standby” mode.
Test Outputs
A1
VF
CS
CA
This menu allows you to
check the operation of
the various pellet boiler
components / outputs.
Using the navigation
arrows, you can turn on
and off the various
components and each
time the respective components is being
activated a check mark will appear in
front of its name. Use the
„Enter”
button
to select the individual components /
outputs.
Test controller imputs
by using this menu.
Menu includes:
Description of Test components/
outputs:
CS
– Clean soot motor;
VF
– motor of the vacuum system for
refueling;
CA
– clean ash motor;
FF
– Fuel Feeder;
BF
– Burner Feeder;
CH
– Central Heating pump;
DHW
– Domestic Hot Water pump;
Ign
– Ignition;
CM
–Cleaning Motor;
Important. This menu is for installers
only and it is active and visible only if the
controller is in „Standby” mode.
11. SETTING OUTPUT MODES OF
OPERATION OF THE PELL PELLET
BURNER CONNECTED TO PELLEBURN
PELLET BOILER
This setting is valid for controller
software version: NPBC-V5M
1.0/1.0