Operating and display elements
11.3
Status indicator
Status indicator (RGB-LED)
Figure 49:
Status indicator
The status indicator (RGB LED) show the device status and the valve position.
The user can set the following LED modes:
•
Valve mode
•
Valve mode with error messages
•
Valve mode with error messages and warnings (factory setting)
•
NAMUR mode
•
LED off
With the IO-Link and AS-Interface variant, the teach function can also be started via the bus com-
munication (see respective parameter list) or with all variants of the REV.3 versions with the Bürkert
Communicator.
The description for setting the LED mode can be found in the section "Setting the LED mode" in the
operating manual.
11.4
Description of the LED modes
11.4.1
Valve mode
Displays in valve mode:
•
Valve position: open, half-way, closed
Valve position
Valve position
status, color
Open
is lit yellow*
Half-way
LED off*
Closed
is lit green*
Table 17:
Valve mode
* Factory setting, selectable colors for the valve position: Off, white, green, blue, yellow, orange, red
english
Type 8691 REV.3