30 - 8640
PROFIBUS-DP
PROFIBUS-DP
The purpose of the bus system is the fast serial linkage of de-central peripherals (valve batteries) with the
central Master (controller). In addition to the Input/Output data, parameter data, configuration data and
diagnosis data is also transferred.
The PROFIBUS-DP is defined in the DIN 19245 T3 standard.
Many PROFIBUS masters (controllers) need a configuration program with which the network structure is
described. e.g., SIEMENS COM ET200 for the S5 controller. These programs require the unit master file
(GSD file) or, as in the case of the above-mentioned Siemens controller, the Type file. Both files are stored
on diskettes, and contain bus-specific data.
Extract of important data for the PROFIBUS-DP
Available Baud rates
9,6; 19,2; 93,75; 187,5; 500; 1500 kBaud
Manufacture’s Number
0081 h
Data quantity without RIO extension
4 input and 3 output bytes
several identifiers possible
(e.g. 10H, 10H, 10H, 10H, 20H, 20H, 20H )
no user-specific parameters
Data quantity with RIO extension
4 input and 3 output bytes for each battery
Byte or bit limits between the individual batteries
with bit limits, user-specific parameters necessary
Summary of Contents for 8640
Page 10: ...8 8640 GENERAL INSTRUCTIONS ...
Page 22: ...20 8640 MODULES FOR CONVENTIONAL CONNECTION TECHNICS ...
Page 58: ...56 8640 PROFIBUS DP ...
Page 98: ...96 8640 FIELD BUS MODULE INTERBUS S ...
Page 118: ...116 8640 SELECAN ...
Page 152: ...150 8640 AS INTERFACE ...
Page 156: ...154 8640 INPUT EXPANSION MODULE FOR TRANSDUCERS ...
Page 178: ...176 8640 INTERNAL BUS EXTENSION ...
Page 189: ......
Page 194: ......
Page 195: ......
Page 196: ...The smart choice of Fluid Control Systems www buerkert com ...