General view
Power supply
Technical earth
LED status display
Field bus connector
DIP switch
Fig.: General view of PROFIBUS-DP field bus module
NOTE
ATTENTION!
Pin 2 of the power supply must be fused with 4A (semi-time lag).
Accessories
Plug connector M12+1 (socket) for the power supply
Order number 917116 D
Power supply
The 4-pole circular connector M12 (plug) for voltage supply is wired as follows.
Pin 1
24 V DC control voltage
Pin 2
24 V DC supply voltage
Pin 3
Ground (GND)
Pin 4
not used
24 V DC control
voltage
24 V DC supply
voltage
GND
Electronices
Inputs
Outputs
To ensure the electro-magnetic compatibility (EMC), connect the screw terminal TE