Page 10
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
BREWING CIRCUIT (cont.)
Set up brewer according to instruc-
tions in section
Adjustments-Brew
Volumes
. (See page 7) Using a stop
watch or second hand, time the
length of the brew cycle. Record
this time inside the top lid. If ser-
vice is ever needed again, use the
time as reference to determine if
time has changed.
Inspect the sprayhead tube and
sprayhead for excessive lime de-
posits. Delime as required.
Refer to
Service - Brew Solenoid
Valve for testing procedures. See
page 16
A) Direction of flow arrow must be
pointing towards brewer.
B) Remove flow control and check
for obstructions. Clear or replace.
1. Brew volume
2. Lime build up
3. Brew Solenoid Valve
4. Flow Control
Consistently low beverage level in
the dispenser or beverage over-
flows dispenser
33030 052600