TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
BREWING CIRCUIT
Brew or sanitize cycle will not start
1. Ready light flashing
2. No water
3. No power or incorrect voltage to
the brewer
4. ON/OFF switch not in the "ON" po-
sition
5. START Switch
6. Low water temperature (Brew
lockout is enabled)
7. Brew solenoid valve
8. Control board
Brewer has shut down due to
malfunction (See Diagnostic Chart
in manual, page 14, or under top
lid of brewer).
Water lines and valves to the brewer
must be open.
Check for voltage across the black
and white terminals at the power
source.
The indicator lamp must be lit
Refer to
Service - Start Switch for
testing procedures. See page 23
Allow brewer to heat until ready
lamp is lit, or disable the brew lock-
out feature. See page 7
Refer to
Service - Brew Solenoid
Valve for testing procedures. See
page 16
Refer to
Service - Control Board for
testing procedures. See page 25