Page 23
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
% DILUTION
This function allows adjustment of the amount of
water that flows passed the grounds. The number
signifies the percentage of the brew volume which
does not flow over the coffee grounds/tea.
Modifying recipes - dilution percentages:
Range: 0% to 90% for all batch sizes
NOTE:
If the brewer is already in the
% DILUTION
screen, it is not necessary to follow steps 1 through 6
in this section, but proceed directly to step 7.
1. Press and hold the ® pad until the display reads
WARMER OFF.
Release the ® pad. Press the ®
until the display reads
REVIEW RECIPES
.
2. Press
YES
to proceed. The display should now
read
NO NAME,
along with
MODIFY
and
NEXT.
3. Press and release
NEXT
to advance to the desired
recipe name to be modified.
REVIEW RECIPES?
NO YES
BATCHES DONE?
NO YES
BATCHES DONE?
NO YES
SET PULSE BREW?
NO YES
BREW MI/M XX.X
(-) DONE (+)
% DILUTION XX
(-) DONE (+)
NO-NAME
MODIFY NEXT
(RECIPE NAME)
MODIFY NEXT
THAT WAS THE
LAST RECIPE
EXIT TO
NEXT FUNCTION
SCREEN
ADVANCES TO ALL OTHER
RECIPE NAMES PROGRAMMED
IN THE BREWER'S MEMORY
WHEN THE LAST RECIPE NAME
IN THE BREWER'S MEMORY IS
DISPLAYED, PRESSING
NEXT
WILL EXIT AND THE DISPLAY
WILL THEN READ:
SEE
MODIFYING
PULSE BREW ON
THE FOLLOWING PAGE
OR PRESS AND RELEASE
ON/OFF PAD TO EXIT THE
% DILUTION SETUP AND
RETURN TO THE MAIN SCREEN
P3214
4. Press and release
MODIFY.
The display should
read
BREW MI/M.
5. Press and release
DONE
. The display should read
BATCHES DONE?
.
6. Press and release
YES
. The display should now
read
% DILUTION
, and a batch light will be blink-
ing. Press and release the batch size to be modi-
fied.
7. Using
(-)
and
(+)
set the amount of dilution water
(percentage) to be dispensed
around
the grounds
for that particular batch size.
8. When finished, press another batch size and re-
peat step #7 for each batch to be modified.
9. When finished setting all batch sizes, press
DONE
.
The display should read
BATCHES DONE?
10. If they are not correct, press and release
NO
to
return to the
% DILUTION
setup screen.
11. If all batch sizes are correct, press
YES
. This will
advance to
SET PULSE BREW.
Another alternative
is to press the "ON/OFF/LOWER" pad to exit the
%
DILUTION
setup and return to the
MAIN SCREEN.
37467 110904