Page 8
41169 120711
"WATER PUMP FAULT
CHECK WATER PUMP"
Water does not drop below level probe
for 90 seconds during brew cycle.
Weak beverage
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
BREWING CIRCUIT (cont.)
1. Sprayhead blockage.
2. Tubing between tank and spray-
head blocked/limed up.
3. Pump/seal leaking.
4. No voltage to pump.
5. Pump defective.
1. Sprayhead
2. Water temperature
Check/replace.
Check/replace.
Check/replace.
Check wiring/CBA.
Replace pump.
A clean sprayhead must be used for
proper extraction.
Allow tank to re-heat.