![Bunn AutoPOD My Cafe AP Service & Repair Manual Download Page 19](http://html1.mh-extra.com/html/bunn/autopod-my-cafe-ap/autopod-my-cafe-ap_service-and-repair-manual_2830807019.webp)
Page 19
Location:
The index motor & sensor are located on the
ejector assembly. FIG 18-1.
Function:
A: Motor drives the pod holder from brew position to
open position to dump position.
B: Photosensor detects position of pod holder by
reading slots in motor disk.
Test Procedures:
1. Go to "TEST INDEX MOTOR" in the "TEST OUTPUTS"
mode.
Press & hold "DUMP" (OPEN/CLOSE button) drives
the pod holder back to the pod ejection position.
Press & hold "LOAD" (HOT WATER button) drives
the pod holder out to the door open position.
• "L" indicates the assembly is in load postion FIG
19-1a/b.
• "
B
"
indicates the assembly is in home postion
FIG 19-2a/b.
• "D" indicates the assembly is in dump postion FIG
19-3a/b.
• " " indicates the photo sensor is not blocked by
the disk.
• " " indicates the photo sensor is blocked by the disk.
EJECTOR ASSEMBLY
FIG. 18-1 INDEX MOTOR/SENSOR - MyCafé AP
B
A
1. With a voltmeter, check voltage across the terminals
of the motor. Activate motor in the "TEST OUTPUTS"
program mode. The indication must be 12 vdc on
all models. Continuity is not a viable test for this
motor.
CONTINUED
41169 120711