BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY

Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:

1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal servers 

and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor. 

2) All other equipment -  2 years parts and 1 year labor plus added warranties as specified below:

 

a) Electronic circuit and/or control boards - parts and labor for 3 years. 

 

b) Compressors on refrigeration equipment - 5 years parts and 1 year labor. 

 

c) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis - parts 

and labor for 4 years or 40,000 pounds of coffee, whichever comes first.

These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be 

commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the 

applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured 

by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, 

improper maintenance or repair, non periodic cleaning and descaling, equipment failures related to poor water quality, 

damage or casualty. In addition, the warranty does not apply to replacement of items subject to normal use including but 

not limited to user replaceable parts such as seals and gaskets. This warranty is conditioned on the Buyer 1) giving BUNN 

prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office 

Box 3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an 

authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under 

warranty.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EX-

PRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY 

OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make 

modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such 

individuals, whether oral or written, do not constitute warranties and should not be relied upon.

If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive op-

tion while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the 

applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair 

is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for 

the equipment.

THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS 

EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION 

AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.

In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of 

use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities 

or services, or any other special, incidental or consequential damages.

392, AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, BrewWISE, BrewWIZARD, BUNN Espress, BUNN 

Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic, BUNN, BUNN with the stylized red line, BUNNlink, Bunn-OMatic, 

Bunn-O-Matic, BUNNserve, BUNNSERVE with the stylized wrench design, Cool Froth, DBC, Dr. Brew stylized Dr. design, 

Dual, Easy Pour, EasyClear, EasyGard,  FlavorGard, Gourmet Ice, Gourmet Juice, High Intensity, iMIX, Infusion Series, In-

tellisteam, My Café, Phase Brew, PowerLogic, Quality Beverage Equipment Worldwide, Respect Earth, Respect Earth with 

the stylized leaf and coffee cherry design, Safety-Fresh, savemycoffee.com, Scale-Pro, Silver Series, Single, Smart Funnel, 

Smart Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in Beverage Equipment Worldwide, ThermoFresh, 

Titan, trifecta, Velocity Brew, A Partner You Can Count On, Air Brew, Air Infusion, Beverage Bar Creator, Beverage Profit 

Calculator, Brew better, not bitter., BUNNSource, Coffee At Its Best, Cyclonic Heating System, Daypart, Digital Brewer 

Control, Nothing Brews Like a BUNN, Pouring Profits, Signature Series, Tea At Its Best, The Horizontal Red Line, Ultra are 

either trademarks or registered trademarks of Bunn-O-Matic Corporation.

Summary of Contents for AutoPOD My Cafe AP

Page 1: ...the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way t...

Page 2: ...ons to this warranty or to make additional warranties that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied...

Page 3: ...Page 3 41169 120711 CONTENTS Warranty 2 Contents 3 Troubleshooting 4 Diagnostics 9 Service 10 Schematics 25...

Page 4: ...ermanent If an intermittent condition is encountered the cause will likely be a switch contact or a loose connection at a terminal or crimp Solenoid removal requires interrupting the water supply to t...

Page 5: ...to solenoid valve 5 Solenoid valve defective 1 Lime build up on probe 2 Water Level Sensing System 1 Refill valve stuck open Make sure water is ON Clean out debris Contact plumber Check wiring CBA Rep...

Page 6: ...up Check wiring Replace Replace heater Check wiring Replace CBA Check replace Check replace Check replace Plumbing lines should not rest on the counter top The brewer must be connected to a cold wate...

Page 7: ...alibrated 3 Flow meter 4 AIR TIME set too low 1 Water shut off 2 Flowmeter inletblocked limedup 3 Flow meter defective 4 No voltage to solenoid valve 5 Solenoid valve defective Brewer has shut down du...

Page 8: ...OBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT cont 1 Sprayhead blockage 2 Tubing between tank and spray head blocked limed up 3 Pump seal leaking 4 No voltage to pump 5 Pump defective 1 Sprayhead 2 Wate...

Page 9: ...ggered when load on motor ex ceeds 1 amp Tripping GFCI breaker 1 Pod s binding pod holder as sembly 2 Debris on sensor blocking optical path 3 Timingdiskcouplerloose slipping 4 No voltage to motor 5 M...

Page 10: ...rvicing except when electrical tests are re quired and the test procedure specifically states to plug in the brewer WARNING Disconnect the brewer from the power source before the removal of any panel...

Page 11: ...Ifvoltageispresent andbrewerdoesnotpower on replace board Removal and Replacement 1 Disconnect brewer from power source 2 DisconnectthecordfromL1 L2onthecontrolboard 3 Disconnect the connectors from...

Page 12: ...areas 4 Connect the voltmeter leads to the coil terminals Turn on the valve with the test mode Set the meter to AC volts The indication should be line voltage when activated If voltage is present as d...

Page 13: ...cement MyCaf AP 1 Remove the top cover and back access panel 2 Drain water from the tank 3 Disconnect all the hoses from the tank 4 Disconnect the wires from tank heater terminals 5 Remove two screws...

Page 14: ...is working correctly check limit thermostat and TCO on 230V models If voltage is not present as described proceed to 4 4 Disconnecttemperatureprobefromcontrolboard Check the resistance across the two...

Page 15: ...i nals of the vent valve Activate valve in the TEST OUTPUTS program mode The indication must be 12 vdc 2 Coil resistance should be 28 8 10 Removal and Replacement 1 Disconnect the brewer from the powe...

Page 16: ...3 Disconnect the brewer from the power source If voltage is present as described circuit is working correctly If voltage is not present as described proceed to 4 4 Disconnect two pin connector from m...

Page 17: ...or Activatemotorinthe TESTOUTPUTS programmode Theindicationmustbe120vdcon all models NOTE 230v models provide 120vdc to the motor 230v models have capacitors installed on motor for CE compliance Conti...

Page 18: ...a DC voltmeter check voltage across the two wiresatJ7onmainCBA Blackprobetoblackwire red probe to red wire Connect the brewer to the power source The indication must be 12 vdc 3 Disconnect the brewer...

Page 19: ...LOAD HOT WATER button drives the pod holder out to the door open position L indicates the assembly is in load postion FIG 19 1a b B indicates the assembly is in home postion FIG 19 2a b D indicates t...

Page 20: ...N INDEX B MOTOR DUMP NEXT LOAD 19 3b DUMP POSITION INDEX D MOTOR DUMP NEXT LOAD FIG 19 2a UNBLOCKED FIG 19 3aBLOCKED EJECTOR ASSEMBLY INDEX L MOTOR DUMP NEXT LOAD FIG 19 1b LOAD POSITION FIG 19 1a UNB...

Page 21: ...k of ejector 7 Disconnect harnesses from index motor sensor and display board 8 Remove 5 screws from housing FIG 20 2 9 Spread back of housing to clear bracket assem bly and slide housing towards fron...

Page 22: ...emove top cover 4 Loosen top Allen screw farthest from motor FIG 21 1 5 Remove plastic plug from ejector floor Insert Al len wrench through hole and loosen bottom Allen screw farthest from motor FIG 2...

Page 23: ...all the way to the back position 9 Power up brewer and Press OPEN CLOSE but ton to close pod door 10 Slightly loosen 2 nuts securing motor mounting bracket to ejector wall FIG 22 3 11 Insert alignmen...

Page 24: ...al assembly 5 If check valve pulls apart remove remaining piece with a spring hook or dental pick 6 Install new check valve with O ring end in first WARNING NEVER RE USE CHECK VALVE AF TER IT HAS BEEN...

Page 25: ...P BREW PUMP INDEX MOTOR AIR PUMPS J5 1 5 6 10 AIR VENT SOLENOID WHI BLU 12V WHI BLU PNK GRN WHI WHI LEVEL PROBE 5V HOT 4 5V COLD TANK HEATER BLU BLK LIMIT THERMOSTAT WHI WHI GND 12V GND 12V 12VDC REVE...

Page 26: ...MPS J5 1 5 6 10 RELAY NC NO C AIR VENT SOLENOID WHI RED WHI RED WHI BLU WHI BLU HOT WATER TANK PNK GRN WHI WHI LEVEL PROBE t 5V HOT 4 5V COLD 5V HOT 4 5V COLD TANK HEATER B L K RED BLK BLK WHI LIMIT T...

Page 27: ...TER TANK PNK GRN WHI WHI LEVEL PROBE t 5V HOT 4 5V COLD 5V HOT 4 5V COLD TANK HEATER B L K W H I WHI BLK BLK RED LIMIT THERMOSTAT WHI BREW TANK W H I B L K BLK LIMIT THERMOSTAT t BLK BLK TANK HEATER S...