Page 17
Location:
The vent valve is located inside the back access panel.
Function:
The water pump (boost)on AutoPod pressurizes the
brew tank during brew cycle. The water pump on My-
Cafe AP pressurizes the sprayhead during brew cycle.
Test Procedures:
1. With a voltmeter, check voltage across the terminals
of the motor. Activate motor in the "TEST OUTPUTS"
program mode. The indication must be 120 vdc on
all models. NOTE: 230v models provide 120vdc to
the motor. 230v models have capacitors installed
on motor for CE compliance.
Continuity is not a viable test for this motor.
Removal and Replacement:
1. Disconnect the brewer from the power source.
2. Loosen clamp.
3. Disconnect harness to motor.
4. Remove clamps and hoses from motor.
5. Install in reverse order.
FIG. 17-1 WATER PUMP - MyCafé AP
FIG. 17-2 WATER PUMP - AutoPod
WATER PUMP
41169 120711