TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
BREWING CIRCUIT
Brew cycle will not start
Consistently low beverage level in
the dispenser or beverage overflows
dispenser.
Brew volume incorrect or incon-
sistent.
"NO FLOW COUNTS
DURING BREW"
No pulses from flow meter.
1. Displays error message
2. No power or incorrect voltage to
the brewer.
3. Low water temperature
(Brew lockout is enabled)
4. Membrane Switch
1. Brew volume
1. Brew volume
2. Brew volume not calibrated.
3. Flow meter.
4. "AIR TIME" set too low.
1. Water shut off.
2. Flow meter/inlet blocked/limed up.
3. Flow meter defective.
4. No voltage to solenoid valve.
5. Solenoid valve defective.
Brewer has shut down due to mal-
function.
Check for correct voltage at the
outlet.
Allow brewer to heat until ready, or
disable the brew lockout feature.
Check/replace.
Adjust Brew volume. NOTE: Volume
adjustments must be made with
sprayhead installed.
Adjust Brew volume. NOTE: Volume
adjustments must be made with
sprayhead installed.
Perform calibration procedure.
Check/replace.
Adjust.
Make sure water is ON.
Check/replace.
Check/replace.
Check wiring/CBA.
Replace solenoid valve.