1
7
1.2.3 Fire protection distances to combustible components
and furniture
Please keep the distances listed in the following table to
flammable components and furniture:
S
park protection / protection of the floor
If the stove is placed on a combustible floor (e
.
g. wood,
laminate, carpet) a floor plate made of non-combustible
material is required.
The floor plate can bei made of different materials such as
safety glass or steel. The bottom plate must overtop the front
of the stove by at least 50 cm (from combustion chamber
opening) and laterally by at least 30 cm.
Side
(besides the stove)
(
2
)
Side
(besides the stove) (
2
)
Back(
1
)
Front
from viewing glass(
4
)
Side up to 40 cm
(in front of the stove) (3)
Side up to 40 cm
(in front of the stove (
3
)
B
4
S Stahl B
4
S Keramik
Back
:
20 cm
(1)
20 cm
(1)
Sides (next to the stove
:
)
2
0 cm
(2)
Sides
Seite (
up to
40 cm
3
0
cm
(2)
4
0 cm
(3)
in front of the stove:
4
0 cm
(3)
Front - from viewing glass:
90 cm
(4)
100 cm
(4)