66
We reserve the right to make any changes due to technical modifications!
Installation and Servicing Instructions Logamax plus GB142-24/30/45/60 • Version 12/2004
Buderus Hydronic Systems • http://www.buderus.net
Servicing
14
z
Loosen the union nut of the gas control valve (see
fig. 83, pos. 1).
z
Pull both retaining clips (see fig. 84, pos. 1) on the
burner cover to open them and remove the burner
cover with the fan unit and the gas control valve.
z
Loosen three screws on the gas control valve (see
fig. 85, pos. 1).
Fig. 83
Loosening the union nut
1
Fig. 84
Loosening the retaining clips
1
Fig. 85
Loosening the screws
1
1
1