Electrical connections
8
25
We reserve the right to make any changes due to technical modifications!
Installation and Servicing Instructions Logamax plus GB142-24/30/45/60 • Version 12/2004
Buderus Hydronic Systems • http://www.buderus.net
EV terminal (external switching contact)
This terminal can be used for example for the safety
switch of floor heating. This protects the floor heating
against too high appliance water temperatures (external
manual reset high limit).
The appliance is shut down when the external switching
contact is opened.
DWV
Terminal for connection of an external 3-way valve.
PK
Connector for the primary loop pump 120V 60Hz.
PS
Connector for the DHW tank pump 120V 60Hz.
PZ
Connector for the DHW recirculating pump 120V 60Hz.
Netz
Main power connector 120V 60Hz.
120-volt connections
CAUTION
Make sure that the power consumption of
each of the terminals 7 – 9 (see circuit
diagram) does not exceed 250 W.