THERMOSTAT CONTROL OPERATION
The thermostat control used on this heater differs from standard thermostats. Standard thermo-
stats simply turn the burner on and off. The thermostat used on this heater senses the room tem-
perature. The thermostat adjusts the amount of gas flow to the burner. This increases or de-
creases the burner flame height. At times the room may exceed the set temperature. If so, the
burner will shut off. The burner will cycle back on when the room temperature drops below the
set temperature. The control knob can be set to any level between LOW and HIGH.
NOTE: The thermostat sensing bulb measures the temperature of air near the heater cabinet.
This may not always agree with room temperature (depending on housing construction, installa-
tion location, room size, open air temperatures, etc.). Frequent use of your heater will let you
determine your own comfort levels.
MANUAL LIGHTING PROCEDURE
1. If the pilot cannot be ignited with the piezo, it can be manually lit with the use of a paper
match and lighter rod.
2. Place the match in the holder and light. With the left hand, depress the control knob coun-
terclockwise to “PILOT”. Hold in.
3. Take rod and light match and ignite PILOT. The PILOT is located behind the right hand
side of the front log.
4. Continue to hold the control knob for an additional one (1) minute to ensure the pilot is lit.