FIREPLACE PREPARATION
The fireplace needs to be prepared before installing the gas logs.
A. Turn off the gas supply to the fireplace.
B. Any outside air ducts on the fireplace shall be permanently closed at the time of the appliance
installation.
WARNING: BEFORE INSTALLING IN A SOLID FUEL BURNING FIREPLACE, THE
CHIMNEY FLUE AND FIREBOX MUST BE CLEANED OF SOOT, CREOSOTE, ASHES
AND LOOSE PAINT BY A QUALIFIED CHIMNEY CLEANER.
WARNING: DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FIREPLACE.
AVOID ANY DRAFTS THAT ALTER BURNER FLAME PATTERN.
LOCATION
Centrally locate the gas logs in the fireplace. Place them deep enough into the fireplace to accomplish
adequate draft (if use as a vented gas log set is planned). Ensure that the front of the logs sit inside the
front edge of the fireplace.
For your convenience, we have furnished two holes in the back bottom bar of the burner base to fasten
it to the floor if you deem it necessary.
NOTE: IF THE EXISTING FIREPLACE IS EQUIPPED WITH A SCREEN IT MUST BE IN
PLACE WHEN THE APPLIANCE IS OPERATING. THE SCREEN SHALL HAVE
ADEQUATE OPENING(S) FOR INTRODUCTION OF AIR FOR COMBUSTION AND
VENTILATION.
NOTE: MAINTAIN PROPER CLEARANCE FOR PURPOSE OF SERVICING, PROPER
INSTALLATION, AND OPERATION.
Mantel Minimum Clearances for a
listed Zero Clearance Firebox or
a Masonry Fireplace.
* WARNING: Canopy model number
MAPSFPC must be used at all times unless a
10-inch mantel is installed at 36-inches
above the fireplace opening. (Can be
obtained from your local dealer or
purchased from the factory.)
16"
13"
10"
FIGURE 1
ANGLE MANTEL
MAX. OF 2 1/2"
21"
17"
14"
FLAT MANTEL