C
−
LRV lift control valve
Product description
300−I−9010212−E−10/08.08
3. Flow−rate measuring system
10
12
S
The oil flows through the flow meter (
12
) in both the up and down
directions
S
The baffle−disc is displaced axially as a function of the flow rate
S
This axial displacement is converted by a non−contacting feedback
transducer (
10
) into an electrical DC signal (the feedback signal),
which is then sent to the C−DELCON
S
The output signal (the feedback) is proportional to the flow rate
S
The controller in the C−DELCON works to match the feedback value
to the demand signal