Technical data and installation
- 2.8 -
KTF/100HPS
Installation of KTF/100HPS with Flat Cable KTF/FLAT
In this type of installation, the devices are powered by an external power supply, using
a KTF/FLAT cable.
(This is the solution typically used for knitting machines)
In this case the INC/DEC graduation can only be performed through a serial line.
The installation of KTF/100HPS devices with flat cable KTF/FLAT is performed
using KTF/FIX rapid clamping brackets which are secured to the back side of KTF
devices.
The KTF/FIX bracket is equipped with contact pins that penetrate the insulation layer
and establish the electrical connection with the individual wires of flat cable, thanks to
the pressure provided by a contrast screw.
The electrical connection between KTF/FIX clamping bracket and KTF/100HPS
device is provided by the KTF10/FIX cable.
The following figures show the installation procedure with KTF/100HPS with flat
cable KTF/FLAT.
Insert the flat cable KTF/FLAT
!
into the rapid clamping bracket
KTF/FIX
"
Tighten the contrast screw
#
,
to obtain the electrical connection
Secure the KTF/FIX bracket to the KTF/100HPS device