Technical data and installation
KTF100/HP
- 2.1 -
2
2
2
2 –––– TECHNICAL DATA AND INSTALLATION
TECHNICAL DATA AND INSTALLATION
TECHNICAL DATA AND INSTALLATION
TECHNICAL DATA AND INSTALLATION
Technical Features
KTF/100HPS device
Power supply voltage
Standard:
24 VDC ± 10%
(max 1500 m/min)
Boost:
32 VDC ± 10%
(max 2500 m/min)
Maximum absorption
0.5A
(during normal operation)
2A
(under stress)
3A
(at start-up)
STOP Output
NPN Open Collector, 200 mA max.
Max. voltage
(INC/DEC
inputs, STOP Output)
30 Vdc
Programmable yarn tension
0.2 ÷ 100.0 gr.
(resolution 0.1 gr.)
Programmable alarms
0.1 ÷ 10 sec.
Integrated keypad
3 push-buttons
2 STOP red LEDs
(1 on the front side + 1 on the rear side)
Signalling
With LCD graphic display
Dimensions
125 x 60 x 40 mm
Operating Temperature range 10° - 60 °C
Power supply KTF/PW4 (6 + 6 outputs)
Power supply voltage
24 Vac ± 20%
Output voltage
2 x 24 Vdc ± 5%
(standard)
2 x 32 Vdc ± 5%
(boost)
Max output current
2 x 20A
(peak)
2 x 10A
(continuous)
Dimensions
115 x 135 x 55 mm
Operating Temperature range 10° - 60 °C
Signalling
8 LEDs: POWER ON, EXC,
INC, DEC, STOP
(Group 1)
INC, DEC, STOP
(Group 2)
Protection
1 fuse 5 x 20 – 10A
SMART KTF 2000 Terminal
Power supply voltage
24 Vdc ± 20%
Maximum absorption
100 mA
Dimensions
135 x 95 x 40 mm
Operating Temperature range 10° - 60 °C
LCD graphic display
80 x 40 mm
Integrated Touch-pad
5 membrane buttons with integrated red LED
Protection
2 fuses 5 x 20 – 1A