Calibration of Tension Sensors
y
TS44.. sensor (on-board of Diaper-Feeder devices)
y
TS55.. sensor (on board of production line)
This operation must be carried out at system commissioning time, and it must be repeated at leas
once a
year.
However, you are kindly recommended to carry out the sensor calibration during every production plant
extraordinary maintenance (
for instance : during the Machine-Stop times for general cleaning and preventive
maintenance of the whole production plant
).
To carry out the calibration procedure, please refer to “Configuration of SM_DIN/DUOLOOP Board”
paragraph (
Note 2
).
We remind you that prior to confirm the execution of OFFSET function, you must remove the yarn from
the loading cell of the involved sensors.
Should the calibration procedure (OFFSET) not be correctly executed (
Tension read after the calibration,
without yarn, not close to 0
), try to touch the loading cell with a finger and check the sensor reaction.
In case of anomalous behavior, replace and re-number the sensor.
Repair
Any repair activity on electronic devices the System (
DIAPERFEEDER IP54 Devices, TS44..
TS55.. and IS3F.. sensors
) must be carried out by specialized BTSR Service Staff.
Any repair attempt carried out by non-authorized personnel will invalidate the warranty terms.