Operation
DIAPERFEEDER IP54
- 3-5 -
Programming the DIAPERFEEDER IP54Devices
The DIAPERFEEDER IP54device offers two programming environments:
1)
SIMPLE
(allows programming exclusively the device main tension)
2)
ADVANCED
(allows programming all the device parameters)
To get access to the programming environment, press and hold down for 3 seconds the
ENTER button, while the device is operating in Control environment.
If you keep the button pressed for less than 3 seconds, the device Firmware version will
temporarily appear on the display.
To switch from
SIMPLE
to
ADVANCED
and viceversa, press and hold down for 3 seconds the
ENTER button.
+
To avoid undesired changes of operating parameters, after the installation of
DIAPERFEEDER IP54 devices and after having setup and checked all the
working parameters in
ADVANCED
programming environment, it is advisable to
activate the
SIMPLE
programming environment, so that when the operator will
subsequently enter the programming environment, he/she will only have the
possibility of changing the main tension (1
st
variable of P1).
General Diagram of Simple Programming Environment
(A)
LFA = Length of Absorbed Yarn in m/min