Troubleshooting and Maintenance
DIAPERFEEDER IP54
- 4-3 -
Faults
Causes
Solutions
The machine is not
stopped by
DIAPERFEEDER
IP54device in case of
yarn breakage
1) The third parameter of the
P1
programming level has been
de-activated (OFF)
2) Wiring problem.
1) Confirm the correct programming of
DIAPERFEEDER IP54 parameters. Check the
correct connection of P1-P2 inputs.
2) If the red LEDs on DIAPERFEEDER IP54
device turn on when the yarn breakage occurs,
than check for correct machine connections.
To check the correct operation of the
DIAPERFEEDER IP54
STOP output press
the
"Control
"
button and confirm the
lighting of red LEDs; if this does not
occur please contact your BTSR reseller
(it could be necessary to send the device
to the BTSR repair centre).
The DIAPERFEEDER
IP54 device does not
communicate with
SMART MATRIX
WINDINGFEEDER
terminal
1) The identification code of
DIAPERFEEDER IP54device
is not correct
2) Failure on SMART MATRIX
WINDINGFEEDER terminal
3) Wiring problem
1) Check that the parameter corresponding to the
identification number
(parameter
P3.4
)
is
correct; if necessary carry out the numbering
procedure using the SMART MATRIX
WINDINGFEEDER terminal or set directly the
identification code on DIAPERFEEDER
IP54device
(parameter
P3.4
)
.
2) Check the correct operation of SMART
MATRIX WINDINGFEEDER terminal using the
numbering procedure described in the SMART
MATRIX WINDINGFEEDER manual.
3) Check the overall device wiring.
ASC1010 COM-
ERROR
displayed on
DIAPERFEEDER
IP54 display
1) Missing communication
between main DSP and
loading cell DSP.
1) Reset the alarm; if the problem persists,
contact your BTSR reseller.
ASC1010 EEP-
ERROR
displayed on
DIAPERFEEDER
IP54 display
1) Loss of calibration data
1) Reset the alarm; if the problem persists,
contact your BTSR reseller.
WATCHDOG
displayed on
DIAPERFEEDER
IP54 display
1) Device internal error
1) Reset the alarm; if the problem persists,
contact your BTSR reseller.
Even if the torque of motor driving the roller rotation is very low and does not involve hazards for
the operator safety, it’s always advisable to lock the motor prior to operate on the devices (yarn
threading, tilt adjustment of coil separation element, etc.) in order to avoid unexpected motor
startup events.
To lock the motor, just press the
button on the DIAPERFEEDER IP54 device and check the
lighting of buttons’ red LEDs and of TS44.. sensor. At the end of the operation, press again the
button and make sure that all the red LEDs turn off.