PABX 18D
26
5 PROGRAMMING THE TYPE APPLICATIONS
Example 2 – “Programming remote activation” type application
Remote activation is programmed for incoming calls from telephone line. Relay 1 is enabled for remote
activation and programmed as monostable with activation 2 seconds. The programming is valid for all the
house-automation scenarios.
Remote activation has been set on telephone line.
( 74 9499 # macrocommand to activate the individual function).
Relay 1 has been programmed for remote activation;
( 75 10 # macrocommand to activate the individual function).
PRI
C
NO
(230V~ 50Hz)
a
b
1
a
b
2
a
b
3
a
b
4
a
b
5
a
b
6
a
b
7
a
b
8
PC
230V~ 50Hz
FAX
M P T R
a
b
U1
3 4
6 A
2 A
COS
= 0,5
M
AUX
EXP
1
T
T
P
M
12V~
C C 1 2 3 4
IN
OUT
C C 1 2 3 4
335818
spa
Patent Pending
230V
15%
50 Hz
0,15 A
PABX 18D cod. 335818
B9743A
9906 6
6 A
2 A
M
COS
=0,5
max
16A
230V~
335916
spa
PABX 28D cod. 335916
to activate this type application use the command:
*
76
*
01 #
Telephone line
RELAY 1
CONTACT
ACTUATOR
RELAY
BASE RELAY