
Terraneo
17
4 SIMPLIFIED PROGRAMMING
4.4 PROGRAMMING THE RELAYS
This programming must be performed to define the mode of operation and/or the timing of the remotely
operated relays.
The command must be performed after the programming access procedure.
After the sequence
75
several pairs of numbers (relay number and operation) can be entered to
program several relays.
Note: the relay number = 0 identifies the internal relay in the exchange
*
*
#
75
Relay number
Operation
0 remotely operated 2 seconds
1 remotely operated 3 minutes
2 remotely operated On/Off
3 not remotely operated 2 seconds
4 not remotely operated 3 minutes
5 not remotely operated On/Off
6 Staircase light 2 seconds
7 Staircase light 3 minutes
from 0 to 8
0 exchange relay
1 relay 1 on module 1
2 relay 2 on module 1
3 relay 3 on module 1
4 relay 4 on module 1
5 relay 1 on module 2
6 relay 2 on module 2
7 relay 3 on module 2
8 relay 4 on module 2
from 0 to 7
Example: relay 0 remotely operated 2 seconds, relay 1 remotely operated On/Off
Lift the receiver
Press the
R
key, you will hear the start-dialling tone
Type:
#
#
Dial the password (e.g. base
1
2
3
4
)
After the start-dialling tone type the Macrocommand:
7 5
0 0
#
1 2
After hearing the confirmation tone hang up
Summary of Contents for Terraneo PABX 18D
Page 97: ...Terraneo 97 NOTES ...
Page 98: ...PABX 18D 98 NOTES ...
Page 99: ......
Page 100: ...BTicino s p a Via Messina 38 20154 MILAN Italy www bticino com ...