5.2 - Maintenance Routines
M2041/5en
SBT-2400 Service Instructions
35
©BTG 2006
4. Remove the 3 bolts (1) at the bottom of the transmitter housing.
5. Carefully extract the measuring module (2).
6. Remove the old O-ring seal from the housing.
7. Insert the new O-ring seal. If needed, use silicon grease to hold the O-ring
seal in place during assembly.
8. Assemble in reverse order.
5.2.1.3
Measuring Module
Measuring Module O-Ring Seal Replacement
.
5.2.1.4
Housing Cover
1. Remove the four screws and remove the cover.
2. Remove the old O-ring seal from the cover.
3. Mount the new O-ring seal. If needed, use silicon grease to keep it in place
during assembly.
4. Assemble in revers order.
Spare parts required:
O-ring seal
Tools required:
Snap ring pliers
2.5 mm allen key/hexagon spanner
4 mm allen key/hexagon spanner
(Small pliers)
(Wise)
Consumable required:
(Silicone grease)
1
2