July 2013 © British Telecommunications plc 2013
Page 23
The alternative port can be selected by accessing the F5 menu.
0 = 443 (default)
1 = 10443
Example. Changing the unit to use Port 10443
Access the button config menu by holding M for 3 seconds.
Repeatedly Press M until F5 is displayed.
Press Set – the display now shows the current setting. i.e. =0 for 443, or =1 for 10443.
Press S to toggle the value to the required setting. i.e. =0 for 443, or =1 for 10443.
Press M to return to the F5 main menu.
Repeatedly press M to scroll to the ?? (save changes question marks)
Press S and the ?? will flash to prompt “Are you sure?”
Press S and the unit will briefly display Pr (program) as the changes are written to
flash. The unit will then restart.
At any time the configuration mode can be exited, without saving changes, by holding down M
for 5 seconds.
Interface Combination (F6)
The unit is supplied configured for primary path GPRS with secondary path PSTN. (Secure 2
and 3)
The unit can be changed to primary path IP with secondary path GPRS. (Secure IP)
This is carried out by changing the value of F6 in the button config.
Example. Changing the unit to Secure IP.
Access the button config menu by holding M for 3 seconds.
Repeatedly Press M until F6 is displayed.
Press Set – the display now shows the current setting. i.e. =0 for GPRS/PSTN, or =1
IP/GPRS.
Press S to toggle the value to the required setting. i.e. =0 for GPRS/PSTN, or =1
IP/GPRS.
Press M to return to the F6 main menu.
Repeatedly press M to scroll to the ?? (save changes question marks)
Press S and the ?? will flash to prompt “Are you sure?”
Press S and the unit will briefly display Pr (program) as the changes are written to
flash. The unit will then restart.
At any time the configuration mode can be exited, without saving changes, by holding down M
for 5 seconds.
Note. The account on the BT Redcare servers must match the interface combination of the
unit. Either IP/GPRS for secure IP, or GPRS/PSTN for secure 2/3.