July 2013 © British Telecommunications plc 2013
Page 33
Galaxy mode.
When the galaxy mode checkbox is ticked then GPOP1 & 2 can directly drive a zone input on
a Honeywell Galaxy panel by connecting the GPOP output through a 1K resistor to the galaxy
zone input. See Fig 18.
Fig 18 - GPOP set to Galaxy mode on web console. Connect to panel via 1K resistor.
Web console status and log screen
Figure 19 - Web Console “Status and log” screen