548J***D
SINGLE PACKAGE ROOFTOP
HEAT PUMP
SIZES 17 AND 24
with PURON
R
(R--410A) REFRIGERANT
Installation Instructions
548J units for installation in the United States contain use of Bryant's 2-speed indoor fan
control system. This complies with the U.S. Department of Energy (DOE) efficiency standard
of 2018.
548J units for installation outside the United States may or may not contain use of the
2-speed indoor fan control system as they are not required to comply with the U.S.
Department of Energy (DOE) efficiency standard of 2018.
For specific details on operation of the Bryant 2-speed indoor fan system refer to the
Variable Frequency Drive (VFD) Factory-Installed Option 2-Speed Motor Control Installation,
Setup and Troubleshooting manual.
NOTE
: Read the entire instruction manual before starting
the installation.
TABLE OF CONTENTS
SAFETY CONSIDERATIONS
2
. . . . . . . . . . . . . . . . . . . .
Rated Indoor Airflow (cfm)
3
. . . . . . . . . . . . . . . . . . . . .
REFRIGERATION SYSTEM COMPONENTS
10
. . . . . .
INSTALLATION
12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Jobsite Survey
12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Step 1 -- Plan for Unit Location
12
. . . . . . . . . . . . . . . . .
Roof Mount
12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Step 2 -- Plan for Sequence of Unit Installation
12
. . . . .
Curb--Mounted Installation
12
. . . . . . . . . . . . . . . . . . .
Pad--Mounted Installation
12
. . . . . . . . . . . . . . . . . . . .
Frame--Mounted Installation
12
. . . . . . . . . . . . . . . . . .
Step 3 -- Inspect Unit
12
. . . . . . . . . . . . . . . . . . . . . . . . . .
Step 4 -- Provide Unit Support
12
. . . . . . . . . . . . . . . . . .
Roof Curb Mount
12
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Slab Mount (Horizontal Units Only)
15
. . . . . . . . . . . .
Alternate Unit Support
(In Lieu of Curb or Slab Mount)
15
. . . . . . . . . . . . . . .
Step 5 -- Field Fabricate Ductwork
15
. . . . . . . . . . . . . . .
Step 6 -- Rig and Place Unit
15
. . . . . . . . . . . . . . . . . . . .
Positioning on Curb
16
. . . . . . . . . . . . . . . . . . . . . . . . .
Step 7 -- Horizontal Duct Connection
16
. . . . . . . . . . . . .
Step 8 -- Install Outside Air Hood -- Factory Option
16
. . .
Step 9 -- Install External Condensate Trap and Line
17
.
Step 10 -- Make Electrical Connections
18
. . . . . . . . . . .
Field Power Supply
18
. . . . . . . . . . . . . . . . . . . . . . . . .
Units Without Factory--Installed
Non--Fused Disconnect
18
. . . . . . . . . . . . . . . . . . . . . .
Units With Factory--Installed
Non--Fused Disconnect
18
. . . . . . . . . . . . . . . . . . . . . .
All Units
21
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Convenience Outlets
22
. . . . . . . . . . . . . . . . . . . . . . . .
Factory--Option Thru--Base Connections
23
. . . . . . . . .
Units Without Thru--Base Connections
23
. . . . . . . . . .
Field Control Wiring
23
. . . . . . . . . . . . . . . . . . . . . . . .
Thermostat
23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Central Terminal Board
24
. . . . . . . . . . . . . . . . . . . . . . .
Commercial Defrost Board
24
. . . . . . . . . . . . . . . . . . . . .
Units Without Thru--Base Connection Kit
26
. . . . . . . .
Heat Anticipator Settings
26
. . . . . . . . . . . . . . . . . . . . .
Transformer Connection for 208--v Power Supply
26
.
Electric Heaters
27
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low--Voltage Control Connections
27
. . . . . . . . . . . . .
EconoMi$er
R
X (Factory--Installed Option)
28
. . . . . . .
Product Description
28
. . . . . . . . . . . . . . . . . . . . . . . . .
System Components
28
. . . . . . . . . . . . . . . . . . . . . . . . .
Specifications
28
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
W7220 Economizer Module
28
. . . . . . . . . . . . . . . . . .
Electrical
28
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inputs
28
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outputs
29
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Environmental
29
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Economizer Module Wiring Details
29
. . . . . . . . . . . .
S--Bus Sensor Wiring
29
. . . . . . . . . . . . . . . . . . . . . . . .
CO
2
Sensor Wiring
30
. . . . . . . . . . . . . . . . . . . . . . . . .
Interface Overview
30
. . . . . . . . . . . . . . . . . . . . . . . . . .
User Interface
30
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Keypad
30
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Menu Structure
31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of Contents for 548J*17 D Series
Page 4: ...4 a548J 015 Fig 2 Unit Dimensional Drawing Size 17 Units ...
Page 5: ...5 a548J 016 Fig 2 Unit Dimensional Drawing Size 17 Units cont ...
Page 6: ...6 a548J 017 Fig 2 Unit Dimensional Drawing Size 17 Units cont ...
Page 7: ...7 a548J 018 Fig 3 Unit Dimensional Drawing Size 24 Units ...
Page 8: ...8 a548J 019 Fig 3 Unit Dimensional Drawing Size 24 Units cont ...
Page 9: ...9 a548J 020 Fig 3 Unit Dimensional Drawing Size 24 Units cont ...
Page 13: ...13 C10139 Fig 7 Roof Curb Details Size 17 Units ...
Page 14: ...14 C10140 Fig 8 Roof Curb Details Size 24 Units ...
Page 19: ...19 a50 9696 Fig 20 548J 17 24 Control Wiring Diagram with VFD Option ...
Page 20: ...20 a50 9697 Fig 21 Typical 548J 17 24 Power Wiring Diagram 208 230V 3 Phase 60Hz unit shown ...
Page 44: ...44 a50 9699 Fig 44 RTU Open System Control Wiring Diagram ...