![Browning BR4GRILL Owner'S Manual Download Page 20](http://html.mh-extra.com/html/browning/br4grill/br4grill_owners-manual_2820329020.webp)
Cooking with Gas
Page 17
3. HAND OPERATION ONLY.
c.
Excess flow Control and Low heat
The propane regulator assembly incorporates an excess flow device designed to supply the grill with
sufficient gas flow under normal conditions yet control excess gas flow.
Rapid changes in pressure can trigger the excess flow device providing a low flame and low
temperature. If the tank valve is turned open to allow gas flow while a burner valve is open, the surge
of pressure will cause the device to activate. The device will remain closed until the pressure is
equalized. This should occur within 5 seconds.
To ensure this does not cause difficulty in lighting the grill, follow these instructions:
1. Make sure all burner valves are “OFF”.
2. Open the tank valve and wait 5 seconds.
3. Light the burner one at a time following the lighting instructions listed on the control box and
page 21.
d. Temperature-Activated Shut-Off
The large plastic nut on the regulator assembly is designed in coordination with a check valve in the
tank valve to shut off the flow of gas when exposed to temperatures between 240-300
℉
.
In the event of a fire or hose break, one of the safeguards will function to control or stop the flow of
gas from the propane tank. Never attempt to use damaged equipment.
Important: Before the use of a fresh tank of gas, please check leakage around the connections
according to section ‘ Checking Gas Leaks ‘ on page 19 and make sure there is no leakage or
vapor accumulation in the cabinet. Make sure all openings around side walls are not blocked.
Important: Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only
install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve.
Other types of caps or plugs may result in leakage of propane.
Gas Requirements
The 2518SLB grill is set and tested at the factory for LPG only. No conversion to other kind of gas is
allowable.
LP Gas Regulator
This grill built for LP-Gas, the regulator supplied is set for 11 in. water column (WC) and is for use
with LP gas only. The factory-supplied regulator and hose must be used with a 20 lb. LP gas tank.
LP GAS System
Contact your gas supplier for a special regulator for bulk gas that fuels other appliances
Gas Consumption
Total gas consumption of this grill with the burner(s) on “HIGH”: Table 1 below.
Summary of Contents for BR4GRILL
Page 103: ......